StabCal™

StabCal › Knowledge

Excavator on a pontoon: why the lift chart is not enough

An excavator on a pontoon does not stand on firm ground. The pontoon inclines with every slew and every load. For that reason the manufacturer's lift chart only tells part of the story: the stability of the pontoon determines how far the machine tilts and how much freeboard is left.

The short answer. The manufacturer's lift chart states how much the machine may lift on firm, level ground. On a pontoon, the inclination of the deck, the wind and the stability of the pontoon itself come on top of that. So you check two things: whether the machine, at the inclination that occurs, still stays within its own chart, and whether the pontoon keeps sufficient freeboard and stability in every phase of the work.

What does the lift chart say?

The lift chart gives the permissible load per load radius (reach) and height, often separately over the side and over the front, sometimes with a mark showing that the value is limited hydraulically. Under ISO 10567 that value for a hydraulic excavator is limited to the smaller of 75 % of the tipping load and 87 % of the hydraulic lifting capacity. The chart assumes a machine standing level on firm ground.

On a pontoon that assumption does not hold. The deck is always slightly inclined, and that inclination changes with the slewing direction, the position of the boom and the load. The machine tips about its tipping line: for a crawler machine the centreline of the outer track rollers (ISO 10567), for a machine on outriggers the outrigger feet; which tipping line governs depends on the direction of the inclination and of the boom. A machine that stays within its chart on shore can therefore have less capacity on an inclined deck. Always consult the machine's operating manual for this: the manufacturer's lift chart remains a limit you must not exceed, and the operating manual may restrict or exclude work on a pontoon. The chart is not the only check.

What does the pontoon do?

A pontoon floats in equilibrium between the weight of everything on it and the buoyancy of the displaced water. Every shift of weight, by slewing, by a load on the hook or by stock on the deck, causes a heeling moment. The pontoon answers with heel and trim. How stiffly it responds depends on the dimensions of the waterplane and the height of the centre of gravity: the metacentric height. A wide, low pontoon is stiff; a narrow pontoon with a tall machine is soft.

The inclination is not the only thing that matters. At every inclination the freeboard on the low side also becomes smaller: the smallest distance between the waterline and the edge of the deck, where the corners of the deck approach the water first. How that works is explained in heel and trim of a pontoon under ES-TRIN 22.07 and stability requirements for floating equipment under ES-TRIN.

Which limits apply to the inclination?

For floating equipment, ES-TRIN 2025/1 Article 22.07 paragraph 1 requires that sufficient residual safety clearance and sufficient residual freeboard are present under the loads that occur, that the sum of the angles of heel and trim does not exceed 10° and that the bottom of the float does not emerge. The residual safety clearance (Article 22.04) is 300 mm for openings that can be closed spray-proof and weathertight and at least 400 mm for openings that cannot be closed that way; the residual freeboard (Article 22.05) is considered sufficient at 300 mm, and it may be smaller if Article 22.08 is demonstrated (see reduced residual freeboard under ES-TRIN 22.08). These limits concern the pontoon. The limits of the machine, in its operating manual, come on top of them and do not replace them. For the proof of stability of a hydraulic excavator, the greatest possible lifting force is to be used (Article 22.07 paragraph 3 letter c), not the load of the day. National requirements of the country or of the competent authority may be stricter.

What counts in a calculation?

Where is the risk?

A common risk is that the machine is placed too heavy or too far from the centre while only the lift chart is looked at. Only when the inclination and the remaining freeboard have been calculated per phase do you see which scenario governs. That can also be the slew towards the side where stock or a load already stands.

How StabCal approaches this

StabCal™ derives the centre of gravity of the machine from the manufacturer's lift chart, following the tipping load principle of ISO 10567, creates scenarios for every phase of the work cycle and calculates per scenario the heel, the trim, the sum of heel and trim and the freeboard at the corners of the deck. The result is a report with input, assumptions and the check with its ES-TRIN source. The manufacturer's lift chart remains a limit you must not exceed; StabCal does not replace it and does not check the tipping stability of the machine. See also what the stability curve of a pontoon shows and what to check when you hire a pontoon.

StabCal checks, per scenario, the criteria from ES-TRIN 2025/1 chapter 22 that are built into StabCal, as far as StabCal can calculate them. Whether an assembly of pontoons is accepted in your situation is decided by an expert or the competent authority; national requirements of the country or of the competent authority may be stricter. StabCal does not give an approval, a declaration of conformity with ES-TRIN or a proof of stability within the meaning of Article 22.07 paragraph 2; a StabCal calculation can form part of that proof. For wind, StabCal uses the specific wind pressure of 0.25 kN/m² under Article 22.07 paragraph 5, with the shape-dependent coefficient of resistance 1.6 (the value for solid-section structures) for all surfaces, and in 24 wind directions instead of only athwartships; that is not more favourable than that paragraph. The safety clearance to openings you do not specify, the tipping stability of the machine, deck pressure, couplings, ground contact and waves are outside the calculation.

Sources

Frequently asked questions

Is the lift chart of the excavator enough for a pontoon?

No. The lift chart applies to a machine on level, firm ground. On a pontoon the deck is always slightly inclined, and that inclination depends on the slewing direction, the position of the boom and the load. For that reason the stability of the pontoon must also be calculated in every phase. The manufacturer's lift chart remains a limit you must not exceed and the operating manual may restrict or exclude work on a pontoon; the chart is not the only check.

How much may an excavator on a pontoon incline?

For floating equipment, ES-TRIN 22.07 paragraph 1 provides that the sum of the angles of heel and trim must not exceed 10°, that sufficient residual freeboard and safety clearance must be present and that the bottom of the float must not emerge. The operating manuals of the pontoon and the machine can set smaller limits, and national requirements may be stricter. Check the current text of the standard and ask the competent authority.

What do you need to know to calculate an excavator on a pontoon?

The weight and dimensions of the pontoon, the weight and lift chart of the machine, the work cycle (positions, slewing directions, loads), the wind and the stock or deck loads. An assumption, such as the centre of gravity of the empty pontoon, must be stated as an assumption.

Read more

Last updated 22 November 2026. StabCal is a tool for work preparation; this article contains general information and is not legal advice or advice for a specific project.

Launch follows shortly

StabCal is in its final test phase. Join the waiting list: you will be the first to hear, and your first basic report is free (one per company, conditions).