StabCal™

StabCal › Knowledge

Reduced residual freeboard for a pontoon under ES-TRIN 22.08

An assembly with a lot of freeboard needs a lot of pontoons. For floating equipment, such as a pontoon with a crane or hydraulic excavator, ES-TRIN allows a smaller residual freeboard under conditions, if you can show that the pontoon remains stable enough that way. This article explains what is required and how you check it per scenario.

The short answer. ES-TRIN 2025/1 (Article 22.05) considers a residual freeboard of 300 mm sufficient. A smaller residual freeboard is only permitted if it is demonstrated that Article 22.08 is met for all operating conditions. These are six criteria (a to f), including a minimum metacentric height, a requirement on the stability curve (GZ curve) and a residual freeboard of at least 0.05 m.

What is the residual freeboard?

The residual freeboard is the smallest vertical distance between the smooth water surface and the side of the deck after the heel and trim resulting from the moments of the work have been taken into account (Article 22.05, paragraph 1, with the moments from 22.07, paragraphs 4 to 9). So it is not the freeboard of the empty pontoon but that of the lowest deck edge in the most unfavourable condition, with machine, deck loads, hoisted load and wind.

Why is reduced freeboard interesting?

With 300 mm as a fixed requirement, a heavy machine or a heavy load quickly makes you use more pontoons than buoyancy requires. More pontoons mean more transport, more coupling work, more space on the water and higher costs. If you can show that the pontoon also meets the criteria of 22.08 with a smaller freeboard, an assembly can sometimes do with fewer pontoons. That is a possibility, not a right: the proof must hold for all operating conditions. For an unusual shape, or equipment with several floating objects, the inspection body may require or allow a different residual freeboard (Article 22.05, paragraph 4).

The criteria of Article 22.08

CriterionWhat is required
aMetacentric height (GM), corrected for free surfaces of liquids, at least 0.15 m.
bBetween 0° and 30° of heel a righting lever of at least 0.30 − 0.28·φn m, with φn the range of stability (the angle at which the stability curve becomes negative) in radians (1° = 0.01745 rad). The range of stability must not be less than 20° (0.35 rad) and counts in the formula for at most 30° (0.52 rad). The requirement thus lies between about 0.20 m (at 20°) and 0.15 m (at 30° or more).
cThe sum of the angles of heel and trim is no more than 10°.
dA residual safety clearance under Article 22.04 (300 mm for openings that can be closed spray-proof and weathertight, 400 mm for openings that cannot be closed that way).
eA residual freeboard of at least 0.05 m.
fBetween 0° and 30° of heel a residual righting lever of at least 0.20 − 0.23·φn m (φn in radians, at most 0.52 rad; about 0.12 m at 20° and 0.08 m at 30° or more): the greatest difference between the curve of the righting levers and that of the heeling levers. If an opening to the interior enters the water at a smaller angle than that of the greatest difference, the requirement applies at that angle.

Criteria b and f are stability curve requirements: they concern the course of the righting lever at larger angles, not only the initial inclination (GM). Therefore also read what the stability curve of a pontoon is and why, for a pontoon, the deck edge entering the water and the bottom emerging bend the curve at small angles already.

For all operating conditions

The text of 22.08 says the proof must hold for all operating conditions. For a pontoon with a hydraulic excavator that means every phase of the work cycle: pre-loading, driving on board, deck stock, hoisting in every boom position and releasing, with the wind and slewing directions that go with it. One favourable scenario is therefore not enough; the most unfavourable one counts.

How StabCal approaches this

If you choose reduced freeboard at input, StabCal™ checks criteria a to f per scenario, with the GZ curve and the range of stability, the residual righting lever, heel and trim, and the safety clearance to the openings you specify on the drawing area. StabCal checks each angle against the less favourable of the 3D curve and the envelope of three cross-sections. The report with derivation shows the GZ curve of the governing scenario degree by degree, so an engineer can recalculate it. In the draft you see in advance whether an assembly meets the criteria StabCal checks. More about the approach: the StabCal home page.

StabCal checks, per scenario, the criteria from ES-TRIN 2025/1 chapter 22 that are built into StabCal, as far as StabCal can calculate them. Whether an assembly of pontoons is accepted in your situation is decided by an expert or the competent authority; national requirements of the country or of the competent authority may be stricter. StabCal does not give an approval, a declaration of conformity with ES-TRIN or a proof of stability within the meaning of Article 22.07 paragraph 2; a StabCal calculation can form part of that proof. For wind, StabCal uses the specific wind pressure of 0.25 kN/m² under Article 22.07 paragraph 5, with the shape-dependent coefficient of resistance 1.6 (the value for solid-section structures) for all surfaces, and in 24 wind directions instead of only athwartships; that is not more favourable than that paragraph. The safety clearance to openings you do not specify, the tipping stability of the machine, deck pressure, couplings, ground contact and waves are outside the calculation.

Sources

Frequently asked questions

May a pontoon always work with less than 300 mm freeboard?

No. ES-TRIN considers 300 mm residual freeboard sufficient. A smaller freeboard is only permitted if it is demonstrated that Article 22.08 is met for all operating conditions. For an unusual shape, or equipment with several floating objects, the inspection body may require or allow a different residual freeboard (Article 22.05, paragraph 4). Whether that is accepted in a concrete situation is decided by an expert or the competent authority.

What is the smallest residual freeboard with reduced freeboard?

Criterion e of Article 22.08 requires a residual freeboard of at least 0.05 m. That is one of six criteria; the metacentric height, the stability curve, the sum of heel and trim and the safety clearance must also be met.

Do I need a stability curve for reduced freeboard?

Yes. Criteria b and f of Article 22.08 concern the righting lever and the residual righting lever between 0° and 30°, and you read those from the stability curve (GZ curve).

Read more

Last updated 21 November 2026. StabCal is a tool for work preparation; this article contains general information and is not legal advice or advice for a specific project.

Launch follows shortly

StabCal is in its final test phase. Join the waiting list: you will be the first to hear, and your first basic report is free (one per company, conditions).

Join the waiting list